Determination of flash point — Modified continuously closed cup flash point (MCCCFP) method
Numéro de référence
ISO/DIS 24966
Edition 1
Projet Norme internationale
ISO/DIS 24966
88708
Projet de Norme internationale au stade enquête auprès des membres de l’ISO.

Résumé

This International Standard specifies a test method for the determination of the flash point of chemicals, lube oils, aviation turbine fuel, diesel fuel, diesel/biodiesel blends and other liquids by a continuously closed cup tester utilizing a specimen size of 2 ml, cup size of 7 ml, with a heating rate of 2.5 °C per minute. This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method. It utilises an electric arc as the ignitor and detects the flash point by pressure measurement.This test method is suitable for testing samples with a flash point from 22,5 °C to 235,5 °C. Flash point determinations below 22,5 °C and above 235,5 °C may be performed, but the precision has not been determined.